Type 241 Underground (coal) Mining Cables

Type 241 Underground (coal) Mining Cables

Application: These reeling and trailing cables are designed to provide a flexible electrical connection between portable or mobile equipment and a point of supply, and they are variously used in underground coal mines, including main feeder cable for continuous miners, pump cable, and power supply cable.
Conductor: Tinned Annealed Copper (Power, Earth and Pilot Cores)
Insulation: R-EP-90
Sheath: H-85-PCP
Voltage: 1.1/1.1 kV   to 11/11 kV
Standards: AS/NZS 1802:2003, AS/NZS 1125,  and  AS/NZS 3808

Type 241.1- 1.1/1.1 kV - 3 Power Core + 3 Earth Core + Pilot Core

Typical Features

Electra Cables

Product Code

Nominal Conductor

Area mm2

Power conductor

Order

Now

Strand Size

No/mm

Nominal Conductor

Diameter

Insulation

Thickness

mm

Nominal Diameter

Over Insulation

mm

 

EC2411 3060

6

84/0.30

3.4

1.5

6.5

 

EC2411 3100

10

77/0.40

4.6

1.5

7.7

 

EC2411 3160

16

126/0.40

5.7

1.6

9

 

EC2411 3250

25

209/0.40

7.2

1.6

10.5

 

EC2411 3350

35

285/0.40

8.5

1.6

11.8

 

EC2411 3500

50

380/0.40

10

1.7

13.5

 

EC2411 3700

70

203/0.67

12

1.8

16

 

EC2411 3950

95

259/0.67

13.2

2

17.6

 

EC2411 31200

120

336/0.67

15.3

2.1

20

 

EC2411 31500

150

427/0.67

17.1

2.3

22.2

 

EC2411 31850

185

518/0.67

19.2

2.5

24.7

 

EC2411 32400

240

672/0.67

21.8

2.8

27.9

 

EC2411 33000

300

854/0.67

14.4

3

30.9

 

Type 241.1 - 1.1/1.1kV - 3 Power Core + 3 Earth Core + Pilot Core

Typical Features

Electra Cables Product Code

Earth conductors

Pilot conductor

Sheath

Approx Mass kg/100m

Order Now

Strand Size No/mm

Area of each screen
mm2

Thickness of SC PCP covering
mm

Strand Size No/mm

Thickness of
EPR covering mm

Thickness including SC PCP Layer
mm

Nominal Overall Diameter
mm

EC2411 3060

15/0.30

1.3

1

24/0.20

0.8

3.8

28.5

115

 

EC2411 3100

24/0.30

1.9

1

24/0.20

0.8

3.8

31.1

155

 

EC2411 3160

39/0.30

3

1

24/0.20

0.8

3.9

34.1

210

 

EC2411 3250

63/0.30

4.7

1

24/0.20

0.8

4.2

37.9

280

 

EC2411 3350

87/0.30

6.4

1

24/0.20

0.8

4.4

41.2

345

 

EC2411 3500

117/0.30

8.5

1

40/0.20

0.8

4.9

45.9

505

 

EC2411 3700

36/0.67

13.8

1

40/0.20

0.8

5.3

52.2

580

 

EC2411 3950

36/0.67

13.8

1

40/0.20

0.8

5.8

56.7

685

 

EC2411 31200

39/0.67

14.8

1.2

40/0.20

0.8

6.3

62.7

839

 

EC2411 31500

51/0.67

19

1.2

40/0.20

0.8

6.7

68.3

1010

 

EC2411 31850

60/0.67

22.2

1.4

40/0.20

0.8

7.3

74.9

1190

 

EC2411 32400

74/0.67

27.1

1.4

40/0.20

0.8

8

83.3

1475

 

EC2411 33000

95/0.67

34.6

1.4

40/0.20

0.8

8.7

91.2

1790

 

Type 241.3 - 3.3/3.3kV - 3 Power Core + 3 Earth Core + Pilot Core

Typical Features

Electra Cables Product Code

Earth conductors

Pilot conductor

Sheath

Approx Mass kg/100m

Order Now

Strand Size No/mm

Area of each screen
mm2

Thickness of SC PCP covering
mm

Stand size No/mm

Thickness
of EPR covering mm

Thickness including SC PCP Layer
mm

Nominal Overall Diameter
mm

EC2413 3160

39/0.30

3

1

24/0.20

0.8

5

43.8

320

 

EC2413 3250

63/0.30

4.7

1

24/0.20

0.8

5.3

47.7

400

 

EC2413 3350

87/0.30

6.4

1

24/0.20

0.8

5.6

51.1

475

 

EC2413 3500

117/0.30

8.5

1.2

24/0.20

0.8

6

55.2

570

 

EC2413 3700

36/0.67

13.8

1.2

24/0.20

0.8

6.4

60.3

710

 

EC2413 3950

45/0.67

16.9

1.2

40/0.20

0.8

6.8

63.8

820

 

EC2413 31200

57/0.67

21.2

1.2

40/0.20

0.8

7.2

69.1

975

 

EC2413 31500

74/0.67

27.1

1.2

40/0.20

0.8

7.6

73.8

1140

 

EC2413 31850

88/0.67

32.1

1.4

40/0.20

0.8

8

79.2

1320

 

EC2413 32400

109/0.67

42

1.4

40/0.20

0.8

8.6

86

1585

 

EC2413 33000

141/0.67

55

1.4

40/0.20

0.8

9.1

92.6

1880

 

Type 241.6 - 6.6/6.6kV - 3 Power Core + 3 Earth Core + Pilot Core

Typical Features

Electra Cables Product Code

Nominal Conductor Area mm2

Power conductor

Order Now

Strand Size No/mm

Nominal Conductor Diameter mm

Insulation Thickness mm

Nominal Diameter Over Insulation mm

EC2416 3160

16

126/0.40

5.7

5

16..5

 

EC2416 3250

25

209/0.40

7.2

5

18

 

EC2416 3350

35

285/0.40

8.5

5

19.3

 

EC2416 3500

50

380/0.40

10

5

20.8

 

EC2416 3700

70

203/0.67

12

5

22.8

 

EC2416 3950

95

259/0.67

13.2

5

24

 

EC2416 31200

120

336/0.67

15.3

5

26.1

 

EC2416 31500

150

427/0.67

17.1

5

27.9

 

EC2416 31850

185

518/0.67

19.2

5

30

 

EC2416 32400

240

672/0.67

21.8

5

32.6

 

EC2416 33000

300

854/0.67

24.4

5

35.2

 

Type 241.6 - 6.6/6.6kV - 3 Power Core + 3 Earth Core + Pilot Core

Typical Features

Product Code

Earth conductors

Pilot conductor

Sheath

Approx
Mass kg/100m

Order Now

Strand
Size
No/ mm

Area of each Screen
mm2

Thickness of SC PCP covering
mm

Stand Size No/ mm

Thickness of EPR Covering
mm

Thickness including SC PCP Layer
mm

Nominal Overall Diameter
mm

EC2416 3160

39/0.30

3

1.4

24/0.20

0.8

6.1

54.9

455

 

EC2416 3250

63/0.30

4.7

1.4

24/0.20

0.8

6.4

58.8

545

 

EC2416 3350

87/0.30

6.4

1.4

24/0.20

0.8

6.7

62.2

630

 

EC2416 3500

117/0.30

8.5

1.4

40/0.20

0.8

7.1

66.2

730

 

EC2416 3700

36/0.67

13.8

1.4

40/0.20

0.8

7.4

71.2

880

 

EC2416 3950

45/0.67

16.9

1.4

40/0.20

0.8

7.9

74.8

1005

 

EC2416 31200

57/0.67

21.2

1.4

40/0.20

0.8

8.3

80.2

1170

 

EC2416 31500

74/0.67

27.1

1.4

40/0.20

0.8

8.6

84.6

1340

 

EC2416 31850

88/0.67

32.1

1.4

40/0.20

0.8

9

90

1535

 

EC2416 32400

109/0.67

42

1.4

40/0.20

0.8

9.6

96.8

1820

 

EC2416 33000

141/0.67

55

1.4 '

40/0.20

0.8

10.2

103.6

2135

 

Type 241.11 - 11/11 kV - 3 Power Core + 3 Earth Core + Pilot Core

Typical Features

Electra Cables Product Code

Nominal Conductor Area mm2

Power conductor

Order Now

Strand Size No/mm

Nominal Conductor Diameter mm

Insulation Thickness mm

Nominal Diameter Over Insulation mm

 EC24111 3250

25

209/0.40

7.2

7.6

23.4

 

 EC24111 3350

35

285/0.40

8.5

7.6

24.7

 

 EC24111 3500

50

380/0.40

10

7.6

26.2

 

 EC24111 3700

70

203/0.67

12

7.6

28.2

 

 EC24111 3950

95

259/0.67

13.2

7.6

29.4

 

 EC24111 31200

120

336/0.67

15.3

7.6

31.5

 

 EC24111 31500

150

427/0.67

17.1

7.6

33.3

 

 EC24111 31850

185

518/0.67

19.2

7.6

35.4

 

Type 241.11 - 11/11 kV - 3 Power Core + 3 Earth Core + Pilot Core

Typical Features

Electra Cables

Product Code

Earth conductors

Pilot conductor

Sheath

Approx
Mass
kg/100m

Order Now

Strand
Size
No/ mm

Area of each Screen
mm2

Thickness of
SC PCP covering
mm

Stand
Size No/ mm

Thickness of EPR Covering
mm

Thickness including
SC PCP Layer
mm

Nominal Overall Diameter
mm

 EC24111 3250

63/0.30

4.7

1.8

24/0.20

0.8

7.8

73.2

785

 

 EC24111 3350

87/0.30

6.4

1.8

24/0.20

0.8

8.1

76.6

880

 

 EC24111 3500

117/0.30

8.5

1.8

40/0.20

0.8

8.5

80.6

990

 

 EC24111 3700

36/0.67

13.8

1.8

40/0.20

0.8

8.9

85.7

1160

 

 EC24111 3950

45/0.67

16.9

1.8

40/0.20

0.8

9.3

89.1

1290

 

 EC24111 31200

57/0.67

21.2

1.8

40/0.20

0.8

9.7

94.4 '

1475

 

 EC24111 31500

74/0.67

27.1

1.8

40/0.20

0.8

10

98.9

1660

 

 EC24111 31850

88/0.67

32.1

1.8

40/0.20

0.8

10.4

104.2

1865